Operational use: | with water from 25°C up to 90°C | • Rollers • Plates • Double walled vessels • Other large consumers |
TECHNICAL DATA: | There are 4 different models available | |||
Temperature range | 25°C up to 90°C with water | |||
Temperature control | self-optimizing, electronic microprocessor controller MP-888 with digital
display of the set and actual value. Automatic temperature monitoring. |
|||
Flow control | electronically, with digital display and automatic control of the minimum flow. | |||
Heating capacity Switchable in stages Autom. switch off |
18 kW 9 / 9 no |
27 kW 9 / 9 / 9 yes |
36 kW 9 / 9 / 9 / 9 yes |
45 kW 9 / 9 / 9 / 18 yes |
Cooling capacity |
increased cooling capacity by switching to the plate heat exchanger standard heat exchanger: 200 kW at 90° plate heat exchanger: 400 kW at 90°C at cooling water temperature approx. 12°C | |||
Pump capacity Pressure mode Vacuum mode |
motor 2,2 kW max. 4,5 bar / max. 200 l/min vacuum max. 8 mH2O |
|||
Filling amount | min. 26 litres, max. 40 litres | |||
Connections Medium Cooling water |
1" BSP male thread 1" BSP male thread, inlet with water filter 1" BSP female thread |
|||
Dimensions (L×W×H) | 1'240 × 480 × 1'400 mm, incl. castors | |||
Weight | approx. 180 kg empty | |||
Colour | silvergrey RAL 7001 |