TECHNICAL DATA: | ||||
Temperature range | up to 160°C continuous temperature with min. 6 bar water inlet pressure required | |||
Temperature control | Self-optimizing, electronic microprocessor controller MP-888 with digital display of the set and actual value. Automatic temperature monitoring. |
|||
Heating capacity Switchable in stages |
12 kW 6 / 6 / 12 kW |
|||
Cooling capacity | Approx. 47,0 kW at +120°C | |||
Pump capacity Pressure mode |
B-pump: 1,8 kW max. 6,5 bar / max. 75 l/min |
|||
Filling | automatic | |||
Connections Heat transfer liquid circuit Cooling water Automatic filing Compressed-air |
3/4” female thread 3/8” female thread 3/8” female thread 1/4" female thread |
|||
Dimensions (mm) | 870 x 360 x 915 incl. castors | |||
Weight (empty) | approx. 120kg | |||
Colour | silvergrey RAL 7001 |